<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sci Rep | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/scientific-publication-category/sci-rep/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Thu, 29 Oct 2026 09:55:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Sci Rep | 2EyesVision</title>
	<link>https://www.2eyesvision.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Experimental characterization, modelling and compensation of temperature effects in optotunable lenses (2023)</title>
		<link>https://www.2eyesvision.com/experimental-characterization-modelling-and-compensation-of-temperature-effects-in-optotunable-lenses/</link>
					<comments>https://www.2eyesvision.com/experimental-characterization-modelling-and-compensation-of-temperature-effects-in-optotunable-lenses/#respond</comments>
		
		<dc:creator><![CDATA[Marrakchi, Y.]]></dc:creator>
		<pubDate>Sat, 28 Jan 2023 14:11:49 +0000</pubDate>
				<guid isPermaLink="false">https://talentiam-programs.com/?post_type=project&#038;p=22988293</guid>

					<description><![CDATA[Marrakchi, Y., Barcala, X., Gambra, E., Aissati, S., Martinez-Ibarburu, I., Dorronsoro C. &#038; Sawides, L. Sci Rep 13, 1575 (2023).]]></description>
										<content:encoded><![CDATA[
<div class="et_pb_section_0 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_0 et_pb_row et_block_row"><div class="et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_divider_0 et_pb_divider et_pb_space et_pb_divider_position_top et_pb_module preset--module--divi-divider--default"><div class="et_pb_divider_internal"></div></div><div class="et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default"><div class="et_pb_text_inner"><h2>Citation</h2>
<p>Marrakchi, Y., Barcala, X., Gambra, E., Aissati, S., Martinez-Ibarburu, I., Dorronsoro C. &amp; Sawides, L.;<b> Experimental characterization, modelling and compensation of temperature effects in optotunable lenses.</b> Sci Rep 13, 1575 (2023). For more information, <a class="link_loma" href="https://doi.org/10.1038/s41598-023-28795-7" target="_blank" rel="noopener">click here.</a></p>
<p>&nbsp;</p>
<h2>Abstract</h2>
<p>Most tunable lenses (TLs) are affected by deviations in optical power induced by external temperature changes or due to internal heating while in use. This study proposes: (1) An experimental characterization method to evaluate the magnitude of the optical power deviations due to internal temperature shifts; (2) three different mathematical models (experimental, polynomial, and optimized) to describe the response of the lens with temperature; (3) predictions of the internal temperature shifts while using the lens in time frames of minutes, seconds, and milliseconds and; (4) a real time optical power compensation tool based on the implementation of the models on a custom voltage electronic driver. The compensation methods were successfully applied to two TL samples in static and dynamic experiments and in hysteresis cycles. After 40 min at a static nominal power of 5 diopters (dpt), the internal temperature exponentially increased by 17 °C, producing an optical power deviation of 1.0 dpt (1.5 dpt when the lens cools down), representing a 20% distortion for heating and 30% for cooling. Modelling and compensation reduced the deviations to 0.2 dpt when heating (0.35 dpt when cooling) and the distortions to 4% and 7%. Similar levels of improvement were obtained in dynamic and hysteresis experiments. Compensation reduced temperature effects by more than 75%, representing a significant improvement in the performance of the lens.</p>
</div></div></div></div></div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/experimental-characterization-modelling-and-compensation-of-temperature-effects-in-optotunable-lenses/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Multifocal acceptance score to evaluate vision: MAS-2EV (2021)</title>
		<link>https://www.2eyesvision.com/multifocal-acceptance-score-evaluate-vision/</link>
					<comments>https://www.2eyesvision.com/multifocal-acceptance-score-evaluate-vision/#respond</comments>
		
		<dc:creator><![CDATA[Barcala, X.]]></dc:creator>
		<pubDate>Wed, 13 Jan 2021 10:30:21 +0000</pubDate>
				<guid isPermaLink="false">https://talentiam-programs.com/?post_type=project&#038;p=22988575</guid>

					<description><![CDATA[Barcala X., Vinas, M., Romero, M., Gambra, E., Mendez-Gonzalez, L., Marcos, S. &#038; Dorronsoro C.. MAS-2EV. Sci Rep 11, 1397 (2021)]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_1 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_1 et_pb_row et_block_row"><div class="et_pb_column_1 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default"><div class="et_pb_text_inner"><h2>Citation</h2>
<p>Barcala X., Vinas, M., Romero, M., Gambra, E., Mendez-Gonzalez, L., Marcos, S. &amp; Dorronsoro C.; <b>Multifocal acceptance score to evaluate vision: MAS-2EV. </b>Sci Rep 11, 1397 (2021). For more information, <a class="link_loma" href="https://www.nature.com/articles/s41598-021-81059-0" target="_blank" rel="noopener">click here.</a></p>
<p>&nbsp;</p>
<h2>Abstract</h2>
<p>We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through different binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modified monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantified using different metrics: overall visual quality, visual degradation at far, visual benefit at near, near stereo benefit, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufficient repeatability and sensitivity to allow differentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo benefit. 46.67% of the subjects ranked binocular bifocal corrections first, and 46.67% of the subjects ranked monovision first. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens fitting or intraocular lens implantation.</p>
</div></div></div></div></div>]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/multifocal-acceptance-score-evaluate-vision/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Visual Simulators replicate vision with multifocal lenses (2019)</title>
		<link>https://www.2eyesvision.com/visual-simulators-replicate-vision/</link>
					<comments>https://www.2eyesvision.com/visual-simulators-replicate-vision/#respond</comments>
		
		<dc:creator><![CDATA[Vinas, M.]]></dc:creator>
		<pubDate>Thu, 07 Feb 2019 16:06:26 +0000</pubDate>
				<guid isPermaLink="false">https://talentiam-programs.com/?post_type=project&#038;p=22988897</guid>

					<description><![CDATA[Vinas M, Benedi C, Sissati C, Pascual D, Vias A, Dorronsoro C, et al. Visual Simulators replicate vision with multifocal lenses. Sci Rep 2019.]]></description>
										<content:encoded><![CDATA[
<div class="et_pb_section_2 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_2 et_pb_row et_block_row"><div class="et_pb_column_2 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_divider_1 et_pb_divider et_pb_space et_pb_divider_position_top et_pb_module preset--module--divi-divider--default"><div class="et_pb_divider_internal"></div></div><div class="et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default"><div class="et_pb_text_inner"><h2 id="Abs1" class="c-article-section__title js-section-title js-c-reading-companion-sections-item">Citation</h2>
<p>Vinas M, Benedi C, Sissati C, Pascual D, Vias A, Dorronsoro C, et al. <b>Visual Simulators replicate vision with multifocal lenses.</b> Sci Rep 2019. For more information, <a class="link_loma" href="https://www.nature.com/articles/s41598-019-38673-w" target="_blank" rel="noopener">click here.</a></p>
<p>&nbsp;</p>
<h2 class="c-article-section__title js-section-title js-c-reading-companion-sections-item">Abstract</h2>
<div id="Abs1-content" class="c-article-section__content">
<p>Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves.</p>
</div>
</div></div></div></div></div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/visual-simulators-replicate-vision/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
