{"id":23000218,"date":"2022-11-30T15:01:33","date_gmt":"2022-11-30T14:01:33","guid":{"rendered":"https:\/\/www.2eyesvision.com\/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022\/"},"modified":"2026-06-22T10:45:21","modified_gmt":"2026-06-22T08:45:21","slug":"evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022","status":"publish","type":"project","link":"https:\/\/www.2eyesvision.com\/es\/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022\/","title":{"rendered":"Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics (2022)"},"content":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.16&#8243; global_colors_info=\u00bb{}\u00bb][et_pb_row _builder_version=\u00bb4.16&#8243; background_size=\u00bbinitial\u00bb background_position=\u00bbtop_left\u00bb background_repeat=\u00bbrepeat\u00bb global_colors_info=\u00bb{}\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.16&#8243; custom_padding=\u00bb|||\u00bb global_colors_info=\u00bb{}\u00bb custom_padding__hover=\u00bb|||\u00bb][et_pb_divider _builder_version=\u00bb4.21.0&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; sticky_enabled=\u00bb0&#8243;][\/et_pb_divider][et_pb_text _builder_version=\u00bb4.16&#8243; background_size=\u00bbinitial\u00bb background_position=\u00bbtop_left\u00bb background_repeat=\u00bbrepeat\u00bb global_colors_info=\u00bb{}\u00bb]<\/p>\n<h2 id=\"Abstract\" class=\"article-heading\">Cita<\/h2>\n<p>Lago, C. M., de Castro, A., Bened\u00ed-Garc\u00eda, C., Aissati, S., &amp; Marcos, S. (2022).;<b> Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics.<\/b> Biomedical Optics Express 2022, 13(12), 6682-6694. Para m\u00e1s informaci\u00f3n, <a class=\"link_loma\" href=\"https:\/\/opg.optica.org\/boe\/fulltext.cfm?uri=boe-13-12-6682&amp;id=522104\" target=\"_blank\" rel=\"noopener\">haga clic aqu\u00ed.<\/a><\/p>\n<p>&nbsp;<\/p>\n<h2 class=\"article-heading\">Resumen<\/h2>\n<p>Los simuladores visuales de \u00f3ptica adaptativa (OA) son excelentes plataformas para la simulaci\u00f3n no invasiva del rendimiento visual con nuevos dise\u00f1os de lentes intraoculares (LIOs), en combinaci\u00f3n con las aberraciones oculares propias del sujeto y el cerebro. Medimos la agudeza visual en foco cruzado en sujetos a trav\u00e9s de una nueva LIO refractiva insertada f\u00edsicamente en una cubeta y proyectada sobre la pupila del ojo, mientras se manipulaban las aberraciones (corregidas, o con aberraci\u00f3n esf\u00e9rica positiva\/negativa a\u00f1adida) utilizando un espejo deformable (ED) en un simulador de OA de desarrollo personalizado. La LIO aument\u00f3 la profundidad de foco (DOF) a 1,53 \u00b1 0,21D, manteniendo una alta Agudeza Visual (AV, \u22120,07 \u00b1 0,05), promediada entre sujetos y condiciones. La modificaci\u00f3n de las aberraciones no alter\u00f3 el rendimiento de la LIO en promedio.<\/p>\n<p>\u00a9 2022 Optica Publishing Group under the terms of the <a href=\"https:\/\/doi.org\/10.1364\/OA_License_v2#VOR-OA\" target=\"_blank\" rel=\"noopener\">Optica Open Access Publishing Agreement<\/a><br \/>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lago, C. M., de Castro, A., Bened\u00c3\u00ad-Garc\u00c3\u00ada, C., Aissati, S., &#038; Marcos, S. (2022). Biomedical Optics Express 2022, 13(12), 6682-6694.<\/p>\n","protected":false},"author":1,"featured_media":22997862,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[452],"project_tag":[],"ppma_author":[29,32,31,25,30],"class_list":["post-23000218","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-biomedical-optics-express"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000218","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/comments?post=23000218"}],"version-history":[{"count":1,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000218\/revisions"}],"predecessor-version":[{"id":23000221,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000218\/revisions\/23000221"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/media\/22997862"}],"wp:attachment":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/media?parent=23000218"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project_category?post=23000218"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project_tag?post=23000218"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/ppma_author?post=23000218"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}