{"id":23000198,"date":"2024-07-12T10:37:33","date_gmt":"2024-07-12T08:37:33","guid":{"rendered":"https:\/\/www.2eyesvision.com\/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation\/"},"modified":"2026-10-29T10:56:02","modified_gmt":"2026-10-29T09:56:02","slug":"simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation","status":"publish","type":"project","link":"https:\/\/www.2eyesvision.com\/es\/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation\/","title":{"rendered":"Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in\u00e2\u20ac\u2018vitro and computational characterization to clinical validation"},"content":{"rendered":"\n<div class=\"et_pb_section_0 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_0 et_pb_row et_block_row\"><div class=\"et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_divider_0 et_pb_divider et_pb_space et_pb_divider_position_top et_pb_module preset--module--divi-divider--default\"><div class=\"et_pb_divider_internal\"><\/div><\/div><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h2 id=\"Abstract\" class=\"article-heading\">Resumen<\/h2>\n<p>Las lentes de contacto multifocales (LCMs) son una de las soluciones para corregir la presbicia, pero su adopci\u00f3n no est\u00e1 generalizada. Para abordar esta situaci\u00f3n, se pueden utilizar simuladores visuales para refinar el proceso de adaptaci\u00f3n. Este estudio tiene como objetivo obtener simulaciones precisas para un simulador visual (SimVis Gekko; 2EyesVision) de dise\u00f1os de LCMs blandas diarias de cuatro fabricantes. La caracterizaci\u00f3n in vitro de estas LCMs \u2014varias potencias y adiciones\u2014 se obtuvo utilizando NIMO TR-1504. A partir de los perfiles de potencia relativa promedio entre potencias, se reconstruyeron mapas de fase y se calcul\u00f3 la m\u00e9trica de Strehl Visual en Foco Cruzado para cada dise\u00f1o de LCM. La simulaci\u00f3n de SimVis Gekko correspondiente a cada dise\u00f1o de LCM se obtuvo computacionalmente y se valid\u00f3 en banco \u00f3ptico. Finalmente, las simulaciones de LCM se validaron cl\u00ednicamente con pacientes pr\u00e9sbitas. Los resultados de la validaci\u00f3n cl\u00ednica muestran una buena concordancia entre las simulaciones de SimVis Gekko y las LCMs reales para las curvas de agudeza visual en foco cruzado (TF-VA) y la AV a tres distancias reales. Todos los dise\u00f1os de LCM mostraron una correlaci\u00f3n parcial superior a 0,90 y un error cuadr\u00e1tico medio inferior a 0,07 logMAR entre la TF-VA de las simulaciones y las LCMs reales en todos los sujetos. En este estudio se confirm\u00f3 la validez del enfoque de simulaci\u00f3n utilizando SimVis Gekko y mediciones in vitro, abriendo la posibilidad de acelerar la adaptaci\u00f3n de LCMs.<\/p>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":9,"featured_media":22998371,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":"","_ppma_block_editor_authors":""},"project_category":[455],"project_tag":[],"ppma_author":[23,24,27,28,32,39,106,152,153,154,151],"class_list":["post-23000198","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-scientific-reports"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/comments?post=23000198"}],"version-history":[{"count":2,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000198\/revisions"}],"predecessor-version":[{"id":23001310,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project\/23000198\/revisions\/23001310"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/media\/22998371"}],"wp:attachment":[{"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/media?parent=23000198"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project_category?post=23000198"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/project_tag?post=23000198"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.2eyesvision.com\/es\/wp-json\/wp\/v2\/ppma_author?post=23000198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}