<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Optical Design and Engineering | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/es/scientific-publication-category/optical-design-and-engineering/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com/es/</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Mon, 22 Jun 2026 08:45:21 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Optical Design and Engineering | 2EyesVision</title>
	<link>https://www.2eyesvision.com/es/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Optical and visual quality of real intraocular lenses physically projected on the patientâ€™s eye (2021)</title>
		<link>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/</link>
					<comments>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/#respond</comments>
		
		<dc:creator><![CDATA[Benedí-García, C.]]></dc:creator>
		<pubDate>Fri, 17 Sep 2021 09:19:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/</guid>

					<description><![CDATA[Benedi-Garcia, C., Vinas, M., Lago, C. M., Aissati S., De Castro, A., Dorronsoro, C, and Marcos, S. Biomed. Opt. Express 12, 6360-6374 (2021).]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_0 et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Benedi-Garcia, C., Vinas, M., Lago, C. M., Aissati S., De Castro, A., Dorronsoro, C, and Marcos, S.; <b>Optical and visual quality of real intraocular lenses physically projected on the patient&#8217;s eye. </b>Biomed. Opt. Express 12, 6360-6374 (2021). Para más información, <a class="link_loma" href="https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-12-10-6360&amp;id=459204" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2 id="Abstract" class="article-heading">Resumen</h2>
<p>Los simuladores visuales tienen como objetivo evaluar la visión con correcciones oftálmicas antes de la prescripción o implantación de lentes intraoculares (LIOs) en el ojo del paciente. En el presente estudio, presentamos el diseño, la implementación y la validación de un nuevo canal LIO-en-cubeta en un simulador visual de Óptica Adaptativa, que proporciona un canal alternativo para la simulación preoperatoria de la visión con LIOs. La LIO se proyecta sobre el plano pupilar del sujeto mediante un sistema Rassow. Una segunda lente, la lente Rassow, compensa una LIO de 20 D, mientras que otras potencias pueden corregirse con un sistema Badal en un rango de 5 D. El nuevo canal se evaluó mediante calidad óptica en foco cruzado (TF) en un ojo artificial en banco y mediante agudeza visual en foco cruzado en pacientes, con varios diseños de LIO (monofocal, trifocal difractiva y de profundidad de foco extendida refractiva).</p>
<p>©2021 Optical Society of America under the terms of the <a href="https://doi.org/10.1364/OA_License_v1#VOR-OA" target="_blank" rel="noopener">OSA Open Access Publishing Agreement</a></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SimVis simulations of multifocal IOL designs based on public-literature data (2021)</title>
		<link>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/</link>
					<comments>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/#respond</comments>
		
		<dc:creator><![CDATA[Sawides, L.]]></dc:creator>
		<pubDate>Sun, 12 Sep 2021 09:15:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/</guid>

					<description><![CDATA[Sawides, L., de Castro, A., Lago, C. M., Barcala, X., Zaytouny, A., Marcos, S., &#038; Dorronsoro, C. Optical Design and Engineering VIII (Vol. 11871, pp. 122-132). SPIE. (2021 Sept.)]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_1 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_1">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_1  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_1 et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Sawides, L., de Castro, A., Lago, C. M., Barcala, X., Zaytouny, A., Marcos, S., &amp; Dorronsoro, C.; <b>SimVis simulations of multifocal IOL designs based on public-literature data. </b>Optical Design and Engineering VIII (Vol. 11871, pp. 122-132). SPIE. (2021 Sept.). Para más información, <a class="link_loma" href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11871/118710O/SimVis-simulations-of-multifocal-IOL-designs-based-on-public-literature/10.1117/12.2595035.short?SSO=1" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2>Resumen</h2>
<p>Dado que existe una gran variedad de diseños de lentes intraoculares (LIOs) disponibles comercialmente en un mercado en crecimiento, seleccionar la mejor LIO para cada paciente se ha convertido en una tarea crucial para un resultado quirúrgico positivo. La información sobre el rendimiento medido o estimado de las lentes comerciales, como la función de transferencia de modulación en foco cruzado (TF-MTF) a una frecuencia y diámetro pupilar determinados, se publica habitualmente. SimVis Gekko, un simulador de visión simultánea de tipo see-through basado en multiplexación temporal, permite a los pacientes experimentar el mundo real a través de diferentes correcciones multifocales antes de la cirugía. Es necesario implementar el mayor número posible de diseños de LIOs disponibles comercialmente en el portafolio de simulaciones de SimVis Gekko para proporcionar una experiencia completa a los pacientes. Desarrollamos un nuevo método para simular visualmente diseños de LIOs mediante multiplexación temporal, basado únicamente en información disponible públicamente (principalmente literatura científica o información regulatoria), utilizando la TF-MTF a 15 cpd como dato de entrada para estimar los coeficientes temporales que proporcionan la mejor aproximación al diseño real de la lente. Validamos el método con mapas de fase sintéticos de correcciones bifocales y trifocales multifocales de área igual segmentada para tres diámetros pupilares de 3 mm, 3,75 mm y 4,5 mm, y lo aplicamos a tres LIOs disponibles comercialmente (lentes trifocales o de profundidad de foco extendida). Se midieron curvas de agudeza visual en foco cruzado (TF-VA) en siete pacientes utilizando las simulaciones SimVis en el SimVis Gekko y coincidieron, en promedio, con las mediciones de AV en foco cruzado en pacientes con LIOs implantadas reportadas en la literatura científica (error RMS promedio en logMAR = 0,05, correspondiente a menos de 3 letras de los optotipos de AV).</p>
<p>&nbsp;</p>
<h3>Palabras clave</h3>
<h4>Visión simultánea; Multiplexación temporal; Simulaciones visuales; MTF; Strehl Visual; Diseños de LIO multifocal; Calidad óptica en foco cruzado</h4></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
