<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Romero, M. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/es/author/romero-m/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com/es/</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Mon, 22 Jun 2026 08:45:22 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Romero, M. | 2EyesVision</title>
	<link>https://www.2eyesvision.com/es/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multifocal acceptance score to evaluate vision: MAS-2EV (2021)</title>
		<link>https://www.2eyesvision.com/es/multifocal-acceptance-score-to-evaluate-vision-mas-2ev-2021/</link>
					<comments>https://www.2eyesvision.com/es/multifocal-acceptance-score-to-evaluate-vision-mas-2ev-2021/#respond</comments>
		
		<dc:creator><![CDATA[Barcala, X.]]></dc:creator>
		<pubDate>Wed, 13 Jan 2021 10:30:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/multifocal-acceptance-score-to-evaluate-vision-mas-2ev-2021/</guid>

					<description><![CDATA[Barcala X., Vinas, M., Romero, M., Gambra, E., Mendez-Gonzalez, L., Marcos, S. &#038; Dorronsoro C.. MAS-2EV. Sci Rep 11, 1397 (2021)]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Barcala X., Vinas, M., Romero, M., Gambra, E., Mendez-Gonzalez, L., Marcos, S. &amp; Dorronsoro C.; <b>Multifocal acceptance score to evaluate vision: MAS-2EV. </b>Sci Rep 11, 1397 (2021). Para más información, <a class="link_loma" href="https://www.nature.com/articles/s41598-021-81059-0" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2>Resumen</h2>
<p>Presentamos una nueva métrica (Puntuación de Aceptación Multifocal, MAS-2EV) para evaluar la visión con correcciones présbitas. El MAS-2EV se basa en un conjunto de imágenes que representan escenas visuales naturales en condiciones diurnas y nocturnas proyectadas en pantallas lejanas y próximas, y un objetivo estéreo de cerca. Los sujetos visualizan y puntúan las imágenes a través de diferentes correcciones binoculares (correcciones monofocales para lejos; correcciones bifocales; monovisión y monovisión modificada) administradas con lentes de contacto blandas (en sujetos jóvenes cicloplegiados) o con un simulador de visión simultánea binocular (en sujetos présbitas y jóvenes cicloplegiados). Las puntuaciones MAS-2EV se representan visualmente en forma de polígonos y se cuantifican mediante diferentes métricas: calidad visual global, degradación visual en lejos, beneficio visual en cerca, beneficio estéreo de cerca, desequilibrio visual cerca-lejos, desequilibrio visual global y una métrica de rendimiento global combinado. Hemos encontrado que el MAS-2EV tiene suficiente repetibilidad y sensibilidad para permitir la diferenciación entre correcciones con solo dos repeticiones, y la duración de la tarea psicofísica (3 min por sujeto/condición/corrección) lo hace utilizable en la clínica. Encontramos que en la mayoría de los sujetos las correcciones bifocales binoculares producen el menor desequilibrio visual y el mayor beneficio estéreo de cerca. El 46,67% de los sujetos clasificó primero las correcciones bifocales binoculares, y el 46,67% de los sujetos clasificó primero la monovisión. El MAS-2EV, especialmente en combinación con simuladores visuales, puede aplicarse para seleccionar correcciones présbitas prospectivas en pacientes antes de la adaptación de lentes de contacto o la implantación de lentes intraoculares.</p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/multifocal-acceptance-score-to-evaluate-vision-mas-2ev-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Optical and Visual Quality With Physical and Visually Simulated Presbyopic Multifocal Contact Lenses (2020)</title>
		<link>https://www.2eyesvision.com/es/optical-and-visual-quality-with-physical-and-visually-simulated-presbyopic-multifocal-contact-lenses-2020/</link>
					<comments>https://www.2eyesvision.com/es/optical-and-visual-quality-with-physical-and-visually-simulated-presbyopic-multifocal-contact-lenses-2020/#respond</comments>
		
		<dc:creator><![CDATA[Vinas, M.]]></dc:creator>
		<pubDate>Thu, 10 Sep 2020 14:28:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/optical-and-visual-quality-with-physical-and-visually-simulated-presbyopic-multifocal-contact-lenses-2020/</guid>

					<description><![CDATA[Vinas M, Aissati S, Sawides L, Akondi V, Gambra E, Dorronsoro C, Karkkainen T, Nankivil D, Marcos M. et al. Trans. Vis. Sci. Tech. 2020.]]></description>
										<content:encoded><![CDATA[<h2>Cita</h2>
<p>Vinas M, Aissati S, Gonzalez-Ramos A, Romero M, Sawides L, Akondi V, Gambra E, Dorronsoro C, Karkkainen T, Nankivil D, Marcos M; <b>Optical and Visual Quality With Physical and Visually Simulated Presbyopic Multifocal Contact Lenses.</b> Trans. Vis. Sci. Tech. 2020;9(10):20. Para más información, <a class="link_loma" href="https://tvst.arvojournals.org/article.aspx?articleid=2770822" target="_blank" rel="noopener">haga clic aquí.</a></p>
<h2></h2>
<h2 class="h6 abstract-title">Resumen</h2>
<h3><strong>Objetivo</strong></h3>
<p>A medida que las lentes de contacto multifocales (LCMs) se expanden como solución para la corrección de la presbicia, se vuelve esencial una mejor comprensión de su rendimiento óptico y visual. Además, proporcionar a los sujetos la experiencia de la visión multifocal antes de la adaptación de lentes de contacto se vuelve fundamental, tanto para probar sistemáticamente diferentes diseños multifocales como para optimizar la selección en la clínica. En este estudio, evaluamos la capacidad de un simulador visual de visión simultánea (SimVis) para representar las LCMs.</p>
<h3><strong>Métodos</strong></h3>
<p>La calidad óptica y visual en foco cruzado (TF) con una LCM asférica de centro-cerca (adiciones baja, media y alta) se midieron utilizando un simulador visual de Óptica Adaptativa policromático multicanal equipado con canales de doble paso, SimVis (multiplexación temporal) y psicofísico para permitir mediciones en banco y en vivo. La calidad óptica TF en banco de las LCMs simuladas por SimVis se obtuvo a partir de imágenes de doble paso (DP) e imágenes de un estímulo en E utilizando ojos artificiales. Diez sujetos présbitas fueron adaptados con la LCM. La AV y las imágenes retinianas DP se midieron TF en un rango de 4,00 D con la LCM en el ojo, y a través de simulaciones SimVis de las mismas LCMs en los mismos sujetos.</p>
<h3><strong>Resultados</strong></h3>
<p>Las mediciones de calidad óptica (en banco y en vivo) y visual (en vivo) TF captaron la esperada ampliación de las curvas con el aumento de la adición. La diferencia RMS entre la lente real y la simulada por SimVis fue de 0,031/0,025 (adición baja), 0,025/0,015 (adición media), 0,019/0,011 (adición alta), para TF DP y TF AV logMAR, respectivamente. Una métrica de similitud de forma muestra valores estadísticos altos (desfase κ = 0), rho = 0,811/0,895 (adición baja), 0,792/0,944 (adición media) y 0,861/0,915 (adición alta) para TF DP/AV logMAR, respectivamente.</p>
<h3><strong>Conclusiones</strong></h3>
<p>Las LCMs expanden teórica y efectivamente la profundidad de foco. Un novedoso simulador, SimVis, capturó el rendimiento óptico y visual en foco cruzado de la LCM en la mayoría de los sujetos. Los simuladores visuales permiten a los sujetos experimentar la visión con lentes multifocales antes de probarlas en el ojo.</p>
<h3><strong>Relevancia Traslacional</strong></h3>
<p>Los simuladores visuales simultáneos permiten a los sujetos experimentar la visión multifocal de forma no invasiva. Demostramos la equivalencia entre las lentes de contacto multifocales reales y las lentes simuladas por SimVis. Los resultados sugieren que SimVis es una técnica adecuada para ayudar en la selección de correcciones présbitas en la práctica de contactología.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/optical-and-visual-quality-with-physical-and-visually-simulated-presbyopic-multifocal-contact-lenses-2020/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>VioBio lab adaptive optics: technology and applications by women vision scientists (2020)</title>
		<link>https://www.2eyesvision.com/es/viobio-lab-adaptive-optics-technology-and-applications-by-women-vision-scientists-2020/</link>
					<comments>https://www.2eyesvision.com/es/viobio-lab-adaptive-optics-technology-and-applications-by-women-vision-scientists-2020/#respond</comments>
		
		<dc:creator><![CDATA[Marcos, S]]></dc:creator>
		<pubDate>Sun, 08 Mar 2020 15:33:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/viobio-lab-adaptive-optics-technology-and-applications-by-women-vision-scientists-2020/</guid>

					<description><![CDATA[Marcos S, BenedÃ­â€GarcÃ­a C, Aissati S, Radhkrishnan A, Romero M, Vedhakrishnan S, Sawides L, Vinas M et al.Â Ophthalmic Physiol Opt 2020.]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_1 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_1">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_1  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_0 et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Marcos S, Benedí-García C, Aissati S, Gonzalez-Ramos AM, Lago CM, Radhkrishnan A, Romero M, Vedhakrishnan S, Sawides L &amp; Vinas M. <b>VioBio lab adaptive optics: technology and applications by women vision scientists.</b> Ophthalmic Physiol Opt 2020; 40: 75-87. Para más información, <a class="link_loma" href="https://doi.org/10.1111/opo.12677" target="_blank" rel="noopener">haga clic aquí.</a></p>
<h2></h2></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="d58504501" class="article-section__header section__title main abstractlang_en main">Resumen</h2>
<div class="article-section__content en main">
<section id="opo12677-sec-0001" class="article-section__content">
<h3 id="opo12677-sec-0001-title" class="article-section__sub-title section1"><strong>Objetivo</strong></h3>
<p>La Óptica Adaptativa permite medir y manipular las aberraciones ópticas del ojo. Revisamos dos configuraciones de Óptica Adaptativa implementadas en el Laboratorio de Óptica Visual y Biofotónica, y presentamos ejemplos de su uso para una mejor comprensión del papel de las aberraciones ópticas en la percepción visual, en ojos normales y tratados.</p>
</section>
<section id="opo12677-sec-0002" class="article-section__content">
<h3 id="opo12677-sec-0002-title" class="article-section__sub-title section1"><strong>Hallazgos recientes</strong></h3>
<p>Se describen dos sistemas (AOI y AOII) que miden las aberraciones oculares con un sensor de frente de onda Hartmann-Shack, que opera en bucle cerrado con un espejo deformable electromagnético, y los estímulos visuales se proyectan en una pantalla visual para mediciones psicofísicas. AOI opera en luz infrarroja (IR). AOII está provisto de una fuente láser de supercontinuo (longitudes de onda IR y visibles), elementos adicionales para simulación (modulador espacial de luz, multiplexación temporal con lentes opto-sintonizables, placas de fase, cubeta para LIOs) y una cámara retiniana de doble paso. Revisamos varios estudios realizados con estos sistemas de OA, incluyendo la evaluación de los beneficios visuales de la corrección de OA, la visión con LIOs multifocales simuladas (LIOMs), las aberraciones ópticas en ojos pseudofáquicos, las aberraciones cromáticas y su impacto visual, y la adaptación neural a las aberraciones oculares.</p>
</section>
<section id="opo12677-sec-0003" class="article-section__content">
<h3 id="opo12677-sec-0003-title" class="article-section__sub-title section1"><strong>Resumen</strong></h3>
<p>Se han medido aberraciones monocromáticas y cromáticas en ojos normales y tratados. Los sistemas de OA han permitido comprender el beneficio visual de corregir las aberraciones en ojos normales y la adaptación del sistema visual a las aberraciones nativas del ojo. Las correcciones oculares como las lentes intraoculares y de contacto modifican las aberraciones de onda. Los sistemas de OA permiten simular la visión con estas correcciones antes de que se implanten o adapten en el ojo, o incluso antes de que se fabriquen, revelando un gran potencial para la industria y la práctica clínica. Este artículo de revisión forma parte de un número especial de Ophthalmic &amp; Physiological Optics sobre mujeres en óptica visual, y está coautorado por todas las científicas del equipo de investigación.</p>
</section>
</div></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/viobio-lab-adaptive-optics-technology-and-applications-by-women-vision-scientists-2020/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pre-operative simulation of post-operative multifocal vision  (2019)</title>
		<link>https://www.2eyesvision.com/es/pre-operative-simulation-of-post-operative-multifocal-vision-2019/</link>
					<comments>https://www.2eyesvision.com/es/pre-operative-simulation-of-post-operative-multifocal-vision-2019/#respond</comments>
		
		<dc:creator><![CDATA[Vinas, M.]]></dc:creator>
		<pubDate>Mon, 21 Oct 2019 14:54:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/pre-operative-simulation-of-post-operative-multifocal-vision-2019/</guid>

					<description><![CDATA[Vinas M, Aissati S, Romero M, Benedi-Garcia C, Garzon N, Poyales F, Dorronsoro C, Marcos S.Â Biomed. Opt. Express 10, 5801-5817 (2019).]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_2 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_2">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_2  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_1 et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Cita</h2>
<p>11. Vinas M, Aissati S, Romero M, Benedi-Garcia C, Garzon N, Poyales F, Dorronsoro C, Marcos S. <b>Pre-operative simulation of post-operative multifocal vision.</b> Biomed. Opt. Express 10, 5801-5817 (2019) Para más información, <a class="link_loma" href="https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-11-5801" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2 class="article-heading">Resumen</h2>
<p>Aunque las lentes intraoculares multifocales (LIOMs) se implantan cada vez más para corregir la presbicia, resulta difícil explicar e imaginar cómo se ve con una corrección multifocal. El presente estudio evalúa la calidad de diversas tecnologías de simulación visual comparando la visión con LIOMs simuladas de forma preoperatoria y la visión con las LIOMs implantadas de forma postoperatoria en los mismos pacientes. Se utilizaron dos plataformas de simulación: (1) un sistema de óptica adaptativa (OA) de desarrollo propio, con dos dispositivos simuladores visuales: un modulador espacial de luz (MEL) y una lente opto-sintonizable que opera en multiplexación temporal (SimVis); y (2) un simulador clínico binocular portátil de gran campo visual SimVis2Eyes (SimVis Gekko, 2Eyes Vision, Madrid, España). Todos los dispositivos fueron programados para simular una LIOM difractiva trifocal (POD F, FineVision, PhysIOL). Se midieron ocho pacientes de forma preoperatoria simulando la lente trifocal y de forma postoperatoria con el implante de la misma LIOM. La agudeza visual (AV) decimal en foco cruzado (TF AV) se midió (1) monocularmente en luz monocromática mediante un procedimiento de elección forzada de cuatro alternativas en el sistema de OA; y (2) binocularmente con un optotipo clínico en luz blanca. Las simulaciones visuales preoperatorias predicen con precisión el rendimiento en TF AV encontrado postoperatoriamente en pacientes con la LIO real implantada. La diferencia RMS media entre las curvas TF de los diferentes simuladores visuales fue 0,05 ± 0,01. La diferencia RMS media entre las curvas de TF AV con SimVis de forma preoperatoria y la LIOM real de forma postoperatoria fue 0,06 ± 0,01 en ambas plataformas, siendo mayor en ojos con catarata (0,08 ± 0,01, promediado entre simuladores) que en ojos con cristalino transparente. En ambos grupos, la forma de las curvas TF es similar entre simuladores y entre las evaluaciones pre y postoperatorias. Las curvas TF se correlacionaron significativamente entre simuladores (desfase k = 0, rho = 0,889), así como con los resultados con la LIOM real implantada (desfase k = 0, rho = 0,853). Las simulaciones visuales son herramientas programables útiles para predecir el rendimiento visual con LIOMs, tanto en entornos de OA como en simuladores clínicos. Las simulaciones visuales preoperatorias y los datos postoperatorios muestran una buena concordancia.</p>
<p>&nbsp;</p>
<p>© 2019 Optical Society of America under the terms of the <a href="https://doi.org/10.1364/OA_License_v1" target="_blank" rel="noopener">OSA Open Access Publishing Agreement</a></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/pre-operative-simulation-of-post-operative-multifocal-vision-2019/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
