<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>de Castro, A. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/es/author/de-castro-a/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com/es/</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Mon, 22 Jun 2026 08:45:21 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>de Castro, A. | 2EyesVision</title>
	<link>https://www.2eyesvision.com/es/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Halo Measurements in Simulated Multifocal Intraocular Lenses</title>
		<link>https://www.2eyesvision.com/es/halo-measurements-in-simulated-multifocal-intraocular-lenses/</link>
					<comments>https://www.2eyesvision.com/es/halo-measurements-in-simulated-multifocal-intraocular-lenses/#respond</comments>
		
		<dc:creator><![CDATA[Papadogiannis, P.]]></dc:creator>
		<pubDate>Thu, 28 May 2026 15:17:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/?post_type=project&#038;p=22999401</guid>

					<description><![CDATA[Abstract Purpose: To quantify the halo size produced by simulated multifocal and extended depth of focus (EDOF) intraocular lenses (IOLs) using a novel psychophysical method, and to compare the results with an established halo assessment tool, computational simulations, and subjective bothersomeness scores. Methods: Ten participants were each presented with ten IOL designs (three trifocals, three EDOFs, three [&#8230;]]]></description>
										<content:encoded><![CDATA[<h2 class="h6 abstract-title">Abstract</h2>
<p><strong>Purpose</strong>: To quantify the halo size produced by simulated multifocal and extended depth of focus (EDOF) intraocular lenses (IOLs) using a novel psychophysical method, and to compare the results with an established halo assessment tool, computational simulations, and subjective bothersomeness scores.</p>
<p><strong>Methods</strong>: Ten participants were each presented with ten IOL designs (three trifocals, three EDOFs, three bifocals, and one monofocal) simulated using SimVis Gekko visual simulator (2EyesVision, Spain). Halo size was quantified using both the established Halo V1.0 software and a custom-developed scrolling method designed for rapid halo assessment. Results were compared with computational predictions derived from Fourier optics. Perceived visual disturbance was evaluated using a shortened version of the Assessment of Intra Ocular Lens Implant Symptoms questionnaire.</p>
<p><strong>Results</strong>: Trifocals produced larger halos than EDOFs, whereas the monofocal generated the smallest. Measurements obtained with Halo V1.0 and scrolling method were highly correlated (<em>r</em> = 0.99) and showed strong agreement with computational estimations (<em>r</em> &gt; 0.92). Halo size increased with IOL addition power by 5 arcmin/diopter. The scrolling method required less time (29.6 ± 16.2 vs. 283 ± 1.7 seconds) and exhibited lower variability (1 ± 0.8 vs. 5.4 ± 5.8 arcmin) compared to Halo V1.0. Subjective disturbance scores correlated strongly with measured halo (<em>r</em> &gt; 0.98).</p>
<p><strong>Conclusions</strong>: SimVis Gekko emulates halo phenomena associated with different IOL designs. The custom scrolling method provides fast, reliable halo assessment with potential for research and clinical application.</p>
<p><strong>Translational Relevance</strong>: Findings support integrating preoperative halo simulation and rapid psychophysical evaluation to enhance personalized IOL selection and patient counseling.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/halo-measurements-in-simulated-multifocal-intraocular-lenses/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Visual simulation of intraocular lenses: from on-bench performance to computational and experimental validations</title>
		<link>https://www.2eyesvision.com/es/visual-simulation-of-intraocular-lenses-from-on-bench-performance-to-computational-and-experimental-validations/</link>
					<comments>https://www.2eyesvision.com/es/visual-simulation-of-intraocular-lenses-from-on-bench-performance-to-computational-and-experimental-validations/#respond</comments>
		
		<dc:creator><![CDATA[Barcala, X.]]></dc:creator>
		<pubDate>Tue, 19 Nov 2024 16:14:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/visual-simulation-of-intraocular-lenses-from-on-bench-performance-to-computational-and-experimental-validations/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_0 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Resumen</h2>
<div>Este estudio presenta un método sistemático para simular diversas lentes intraoculares (LIOs) disponibles en el mercado. Se evaluaron cinco LIOs (dos trifocales, una bifocal, una monofocal mejorada y una de profundidad de foco extendida (EDOF)) en términos de Strehl Visual en foco cruzado (TFVS) utilizando el dispositivo OptiSpheric IOL PRO2 (Trioptics GmbH). A continuación, se calcularon el TFVS estimado (ETFVS) y los coeficientes temporales necesarios para la multiplexación temporal, y mediante un proceso iterativo se obtuvo el TFVS de SimVis. Finalmente, se utilizó un focímetro de alta velocidad para medir las respuestas de la lente opto-sintonizable a los perfiles temporales, y se obtuvo el TFVS experimental de SimVis. Los resultados se analizan en términos de ETFVS (calculado a partir del VSR-OTF), TFVS de SimVis (calculado a partir de los coeficientes temporales mediante multiplexación temporal) y TFVS experimental de SimVis (obtenido del sistema de focímetro de alta velocidad). Las curvas ETFVS y TFVS de SimVis demostraron una excelente alineación en todas las LIOs con coeficientes de correlación cruzada >0,94. De manera similar, las curvas TFVS experimental de SimVis y TFVS de SimVis mostraron alta correlación con coeficientes de correlación cruzada >0,97 y error cuadrático medio (RMSE) <0,05 para cada lente. Demostramos que diferentes diseños de LIOs pueden simularse visualmente utilizando su TFVS para obtener los coeficientes temporales correspondientes para simulaciones mediante multiplexación temporal usando la tecnología SimVis.</div>
<div>
<div>&nbsp;</div>
</div></div>
			</div><div class="et_pb_module et_pb_divider et_pb_divider_1 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Â </h2>
<div>
<div>
<div>Â© 2024 Optica Publishing Group under the terms of theÂ <a id="m_9001424378883109824m_-2949539307438703636OWA99b622fd-fbf8-136c-2074-9a97714509d7" href="https://doi.org/10.1364/OA_License_v2#VOR-OA" target="_blank" rel="noopener" data-saferedirecturl="https://www.google.com/url?q=https://doi.org/10.1364/OA_License_v2%23VOR-OA&amp;source=gmail&amp;ust=1732117527761000&amp;usg=AOvVaw2tnLRgTx7Jd4XO6GqEJfnN">Optica Open Access Publishing Agreement</a></div>
</div>
</div>
<div>
<div>Â </div>
</div></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/visual-simulation-of-intraocular-lenses-from-on-bench-performance-to-computational-and-experimental-validations/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Simulation of daily soft multifocal contact lenses using SimVis Gekko: from inâ€‘vitro and computational characterization to clinical validation</title>
		<link>https://www.2eyesvision.com/es/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation/</link>
					<comments>https://www.2eyesvision.com/es/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation/#respond</comments>
		
		<dc:creator><![CDATA[Barcala, X.]]></dc:creator>
		<pubDate>Fri, 12 Jul 2024 08:37:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_1 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_1">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_1  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_2 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Resumen</h2>
<p>Las lentes de contacto multifocales (LCMs) son una de las soluciones para corregir la presbicia, pero su adopción no está generalizada. Para abordar esta situación, se pueden utilizar simuladores visuales para refinar el proceso de adaptación. Este estudio tiene como objetivo obtener simulaciones precisas para un simulador visual (SimVis Gekko; 2EyesVision) de diseños de LCMs blandas diarias de cuatro fabricantes. La caracterización in vitro de estas LCMs —varias potencias y adiciones— se obtuvo utilizando NIMO TR-1504. A partir de los perfiles de potencia relativa promedio entre potencias, se reconstruyeron mapas de fase y se calculó la métrica de Strehl Visual en Foco Cruzado para cada diseño de LCM. La simulación de SimVis Gekko correspondiente a cada diseño de LCM se obtuvo computacionalmente y se validó en banco óptico. Finalmente, las simulaciones de LCM se validaron clínicamente con pacientes présbitas. Los resultados de la validación clínica muestran una buena concordancia entre las simulaciones de SimVis Gekko y las LCMs reales para las curvas de agudeza visual en foco cruzado (TF-VA) y la AV a tres distancias reales. Todos los diseños de LCM mostraron una correlación parcial superior a 0,90 y un error cuadrático medio inferior a 0,07 logMAR entre la TF-VA de las simulaciones y las LCMs reales en todos los sujetos. En este estudio se confirmó la validez del enfoque de simulación utilizando SimVis Gekko y mediciones in vitro, abriendo la posibilidad de acelerar la adaptación de LCMs.</div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-inaevitro-and-computational-characterization-to-clinical-validation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Optical beam scanner with reconfigurable non-mechanical control of beam position, angle, and focus for low-cost whole-eye OCT imaging (2023)</title>
		<link>https://www.2eyesvision.com/es/optical-beam-scanner-with-reconfigurable-non-mechanical-control-of-beam-position-angle-and-focus-for-low-cost-whole-eye-oct-imaging-2023/</link>
					<comments>https://www.2eyesvision.com/es/optical-beam-scanner-with-reconfigurable-non-mechanical-control-of-beam-position-angle-and-focus-for-low-cost-whole-eye-oct-imaging-2023/#respond</comments>
		
		<dc:creator><![CDATA[Urizar, P.]]></dc:creator>
		<pubDate>Fri, 04 Aug 2023 08:04:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/optical-beam-scanner-with-reconfigurable-non-mechanical-control-of-beam-position-angle-and-focus-for-low-cost-whole-eye-oct-imaging-2023/</guid>

					<description><![CDATA[MarÃ­a Pilar Urizar, Enrique Gambra, Alberto de Castro, Ãlvaro de la PeÃ±a, Onur Cetinkaya, Susana Marcos, and Andrea Curatolo Â· Optica. ]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_2 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_2">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_2  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_3 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Resumen</h2>
<p>La tomografía de coherencia óptica (OCT) de ojo completo es una herramienta prometedora en biometría ocular para la planificación de la cirugía de cataratas, el diagnóstico del glaucoma y los estudios de progresión de la miopía. Sin embargo, los sistemas OCT convencionales están configurados para realizar exploraciones del segmento anterior o posterior del ojo y no pueden cambiar fácilmente entre las dos configuraciones sin añadir o intercambiar componentes ópticos para tener en cuenta la refracción de la óptica del ojo. Incluso en los sistemas OCT de ojo completo más avanzados, las configuraciones de exploración están preseleccionadas y no pueden reconfigurarse dinámicamente. En este trabajo, presentamos el diseño, la optimización y la validación experimental de un escáner de haz óptico reconfigurable y de bajo coste basado en tres lentes electrosintonizables, capaz de controlar de forma no mecánica la posición, el ángulo y el foco del haz. Derivamos la teoría analítica detrás de su control. Demostramos su uso para realizar imágenes alternadas del segmento anterior y posterior mediante una transición fluida entre un escáner de haz enfocado telecéntrico y un escáner de haz colimado angular. Caracterizamos los perfiles de haz correspondientes y registramos imágenes OCT de ojo completo en un ojo modelo y en un ojo de conejo <i>ex vivo</i>, observando características comparables a las obtenidas con escáneres OCT anterior y posterior convencionales. El escáner de haz propuesto reduce la complejidad y el coste de otros escáneres de ojo completo y es muy adecuado para la biometría ocular en 2D. Además, con la versatilidad añadida de la reconfiguración fluida del escáner, su uso puede ampliarse fácilmente a otras aplicaciones oftálmicas y más allá.</p>
<p>© 2023 Optica Publishing Group under the terms of the <a href="https://doi.org/10.1364/OA_License_v2#VOR-OA" target="_blank" rel="noopener">Optica Open Access Publishing Agreement</a></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/optical-beam-scanner-with-reconfigurable-non-mechanical-control-of-beam-position-angle-and-focus-for-low-cost-whole-eye-oct-imaging-2023/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics (2022)</title>
		<link>https://www.2eyesvision.com/es/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022/</link>
					<comments>https://www.2eyesvision.com/es/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022/#respond</comments>
		
		<dc:creator><![CDATA[Lago, C. M.]]></dc:creator>
		<pubDate>Wed, 30 Nov 2022 14:01:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022/</guid>

					<description><![CDATA[Lago, C. M., de Castro, A., BenedÃ­-GarcÃ­a, C., Aissati, S., &#038; Marcos, S. (2022). Biomedical Optics Express 2022, 13(12), 6682-6694.]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_3 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_3">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_3  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_4 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Cita</h2>
<p>Lago, C. M., de Castro, A., Benedí-García, C., Aissati, S., &amp; Marcos, S. (2022).;<b> Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics.</b> Biomedical Optics Express 2022, 13(12), 6682-6694. Para más información, <a class="link_loma" href="https://opg.optica.org/boe/fulltext.cfm?uri=boe-13-12-6682&amp;id=522104" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2 class="article-heading">Resumen</h2>
<p>Los simuladores visuales de óptica adaptativa (OA) son excelentes plataformas para la simulación no invasiva del rendimiento visual con nuevos diseños de lentes intraoculares (LIOs), en combinación con las aberraciones oculares propias del sujeto y el cerebro. Medimos la agudeza visual en foco cruzado en sujetos a través de una nueva LIO refractiva insertada físicamente en una cubeta y proyectada sobre la pupila del ojo, mientras se manipulaban las aberraciones (corregidas, o con aberración esférica positiva/negativa añadida) utilizando un espejo deformable (ED) en un simulador de OA de desarrollo personalizado. La LIO aumentó la profundidad de foco (DOF) a 1,53 ± 0,21D, manteniendo una alta Agudeza Visual (AV, −0,07 ± 0,05), promediada entre sujetos y condiciones. La modificación de las aberraciones no alteró el rendimiento de la LIO en promedio.</p>
<p>© 2022 Optica Publishing Group under the terms of the <a href="https://doi.org/10.1364/OA_License_v2#VOR-OA" target="_blank" rel="noopener">Optica Open Access Publishing Agreement</a></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/evaluating-the-effect-of-ocular-aberrations-on-the-simulated-performance-of-a-new-refractive-iol-design-using-adaptive-optics-2022/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Optical and visual quality of real intraocular lenses physically projected on the patientâ€™s eye (2021)</title>
		<link>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/</link>
					<comments>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/#respond</comments>
		
		<dc:creator><![CDATA[Benedí-García, C.]]></dc:creator>
		<pubDate>Fri, 17 Sep 2021 09:19:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/</guid>

					<description><![CDATA[Benedi-Garcia, C., Vinas, M., Lago, C. M., Aissati S., De Castro, A., Dorronsoro, C, and Marcos, S. Biomed. Opt. Express 12, 6360-6374 (2021).]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_4 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_4">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_4  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_5 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_5  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Benedi-Garcia, C., Vinas, M., Lago, C. M., Aissati S., De Castro, A., Dorronsoro, C, and Marcos, S.; <b>Optical and visual quality of real intraocular lenses physically projected on the patient&#8217;s eye. </b>Biomed. Opt. Express 12, 6360-6374 (2021). Para más información, <a class="link_loma" href="https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-12-10-6360&amp;id=459204" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2 id="Abstract" class="article-heading">Resumen</h2>
<p>Los simuladores visuales tienen como objetivo evaluar la visión con correcciones oftálmicas antes de la prescripción o implantación de lentes intraoculares (LIOs) en el ojo del paciente. En el presente estudio, presentamos el diseño, la implementación y la validación de un nuevo canal LIO-en-cubeta en un simulador visual de Óptica Adaptativa, que proporciona un canal alternativo para la simulación preoperatoria de la visión con LIOs. La LIO se proyecta sobre el plano pupilar del sujeto mediante un sistema Rassow. Una segunda lente, la lente Rassow, compensa una LIO de 20 D, mientras que otras potencias pueden corregirse con un sistema Badal en un rango de 5 D. El nuevo canal se evaluó mediante calidad óptica en foco cruzado (TF) en un ojo artificial en banco y mediante agudeza visual en foco cruzado en pacientes, con varios diseños de LIO (monofocal, trifocal difractiva y de profundidad de foco extendida refractiva).</p>
<p>©2021 Optical Society of America under the terms of the <a href="https://doi.org/10.1364/OA_License_v1#VOR-OA" target="_blank" rel="noopener">OSA Open Access Publishing Agreement</a></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/optical-and-visual-quality-of-real-intraocular-lenses-physically-projected-on-the-patientaes-eye-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SimVis simulations of multifocal IOL designs based on public-literature data (2021)</title>
		<link>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/</link>
					<comments>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/#respond</comments>
		
		<dc:creator><![CDATA[Sawides, L.]]></dc:creator>
		<pubDate>Sun, 12 Sep 2021 09:15:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/</guid>

					<description><![CDATA[Sawides, L., de Castro, A., Lago, C. M., Barcala, X., Zaytouny, A., Marcos, S., &#038; Dorronsoro, C. Optical Design and Engineering VIII (Vol. 11871, pp. 122-132). SPIE. (2021 Sept.)]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_5 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_5">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_5  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_6 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_6  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Sawides, L., de Castro, A., Lago, C. M., Barcala, X., Zaytouny, A., Marcos, S., &amp; Dorronsoro, C.; <b>SimVis simulations of multifocal IOL designs based on public-literature data. </b>Optical Design and Engineering VIII (Vol. 11871, pp. 122-132). SPIE. (2021 Sept.). Para más información, <a class="link_loma" href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11871/118710O/SimVis-simulations-of-multifocal-IOL-designs-based-on-public-literature/10.1117/12.2595035.short?SSO=1" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2>Resumen</h2>
<p>Dado que existe una gran variedad de diseños de lentes intraoculares (LIOs) disponibles comercialmente en un mercado en crecimiento, seleccionar la mejor LIO para cada paciente se ha convertido en una tarea crucial para un resultado quirúrgico positivo. La información sobre el rendimiento medido o estimado de las lentes comerciales, como la función de transferencia de modulación en foco cruzado (TF-MTF) a una frecuencia y diámetro pupilar determinados, se publica habitualmente. SimVis Gekko, un simulador de visión simultánea de tipo see-through basado en multiplexación temporal, permite a los pacientes experimentar el mundo real a través de diferentes correcciones multifocales antes de la cirugía. Es necesario implementar el mayor número posible de diseños de LIOs disponibles comercialmente en el portafolio de simulaciones de SimVis Gekko para proporcionar una experiencia completa a los pacientes. Desarrollamos un nuevo método para simular visualmente diseños de LIOs mediante multiplexación temporal, basado únicamente en información disponible públicamente (principalmente literatura científica o información regulatoria), utilizando la TF-MTF a 15 cpd como dato de entrada para estimar los coeficientes temporales que proporcionan la mejor aproximación al diseño real de la lente. Validamos el método con mapas de fase sintéticos de correcciones bifocales y trifocales multifocales de área igual segmentada para tres diámetros pupilares de 3 mm, 3,75 mm y 4,5 mm, y lo aplicamos a tres LIOs disponibles comercialmente (lentes trifocales o de profundidad de foco extendida). Se midieron curvas de agudeza visual en foco cruzado (TF-VA) en siete pacientes utilizando las simulaciones SimVis en el SimVis Gekko y coincidieron, en promedio, con las mediciones de AV en foco cruzado en pacientes con LIOs implantadas reportadas en la literatura científica (error RMS promedio en logMAR = 0,05, correspondiente a menos de 3 letras de los optotipos de AV).</p>
<p>&nbsp;</p>
<h3>Palabras clave</h3>
<h4>Visión simultánea; Multiplexación temporal; Simulaciones visuales; MTF; Strehl Visual; Diseños de LIO multifocal; Calidad óptica en foco cruzado</h4></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/simvis-simulations-of-multifocal-iol-designs-based-on-public-literature-data-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology (2021)</title>
		<link>https://www.2eyesvision.com/es/simulating-outcomes-of-cataract-surgery-important-advances-in-ophthalmology-2021/</link>
					<comments>https://www.2eyesvision.com/es/simulating-outcomes-of-cataract-surgery-important-advances-in-ophthalmology-2021/#respond</comments>
		
		<dc:creator><![CDATA[Marcos, S]]></dc:creator>
		<pubDate>Tue, 13 Apr 2021 09:26:45 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/simulating-outcomes-of-cataract-surgery-important-advances-in-ophthalmology-2021/</guid>

					<description><![CDATA[Marcos, S., Martinez, E., Vinas, M., de Castro, A., Dorronsoro, C., Pil Bang, S., Yoon, G., Artal, P.Â Annual Review of Biomedical Engineering 2021.]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_6 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_6">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_6  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_7 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_7  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cita</h2>
<p>Marcos, S., Martinez-Enriquez, E., Vinas, M., de Castro, A., Dorronsoro, C., Pil Bang, S., Yoon, G., Artal, P.; <b>Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology. </b>Annual Review of Biomedical Engineering 2021 23:1, 277-306. Para más información, <a class="link_loma" href="https://www.annualreviews.org/doi/pdf/10.1146/annurev-bioeng-082420-035827" target="_blank" rel="noopener">haga clic aquí.</a></p>
<p>&nbsp;</p>
<h2>Resumen</h2>
<p>A medida que el ojo humano envejece, el cristalino se endurece (presbicia) y se opacifica (catarata), lo que requiere su sustitución por un cristalino artificial [lente intraocular (LIO)]. La cirugía de cataratas es el procedimiento quirúrgico más frecuentemente realizado en el mundo. El aumento en los diseños de LIO no ha ido acompañado en la práctica por una sofisticación de los métodos de selección de LIO, que se basan en mediciones anatómicas limitadas del ojo y en la interpretación del cirujano de las necesidades y expectativas del paciente. Proponemos que el futuro de la selección de LIO estará guiado por la imagen cuantitativa en 3D del cristalino para mapear las opacidades del cristalino, anticipar la posición de la LIO y desarrollar modelos oculares completamente personalizados para la selección de LIO basada en trazado de rayos. Por otro lado, los simuladores visuales (en los que los diseños de LIO se programan en elementos activos) permiten a los pacientes experimentar la visión prospectiva antes de la cirugía y tomar decisiones más informadas sobre qué LIO elegir. La imagen cuantitativa y las simulaciones ópticas y visuales de los resultados postquirúrgicos permitirán seleccionar tratamientos óptimos para el paciente sometido a cirugía de cataratas moderna.</p>
<p>&nbsp;</p>
<h3>Palabras clave</h3>
<h4>lente intraocular; cirugía de cataratas; imagen del segmento anterior; tomografía de coherencia óptica; simulación visual; óptica adaptativa</h4></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/es/simulating-outcomes-of-cataract-surgery-important-advances-in-ophthalmology-2021/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
