<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sanchez-Gonzalez, A. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/author/sanchez-gonzalez-a/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Wed, 23 Aug 2023 09:29:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Sanchez-Gonzalez, A. | 2EyesVision</title>
	<link>https://www.2eyesvision.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Experimental simulation of simultaneous vision. Invest Ophthalmol Vis Sci (2013)</title>
		<link>https://www.2eyesvision.com/experimental-simulation-of-simultaneous-vision-invest-ophthalmol-vis-sci/</link>
					<comments>https://www.2eyesvision.com/experimental-simulation-of-simultaneous-vision-invest-ophthalmol-vis-sci/#respond</comments>
		
		<dc:creator><![CDATA[de Gracia, P.]]></dc:creator>
		<pubDate>Thu, 17 Jan 2013 09:36:50 +0000</pubDate>
				<guid isPermaLink="false">https://talentiam-programs.com/?post_type=project&#038;p=22988917</guid>

					<description><![CDATA[de Gracia P, Dorronsoro C, Sanchez-Gonzalez A, Sawides L, Marcos S. Experimental simulation of simultaneous vision. Invest Ophthalmol VS.]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_0 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Citation</h2>
<p>de Gracia P, Dorronsoro C, Sanchez-Gonzalez A, Sawides L, Marcos S. <b>Experimental simulation of simultaneous vision.</b> Invest Ophthalmol Vis Sci 2013 Jan 17;54(1):415-422. For more information, <a class="link_loma" href="http://www.vision.csic.es/Publications/Articles/Experimental%20Simulation%20of%20Simultaneous%20Vision.pdf" target="_blank" rel="noopener">click here.</a></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Abstract</h2>
<h3><strong>Purpose</strong></h3>
<p>To present and validate a prototype of an optical instrument that allows experimental simulation of pure bifocal vision. To evaluate the influence of different power additions on image contrast and visual acuity.</p>
<h3><strong>Method</strong></h3>
<p>The instrument provides the eye with two superimposed images, aligned and with the same magnification, but with different defocus states. Subjects looking through the instrument are able to experience pure simultaneous vision,<br />with adjustable refractive correction and addition power. The instrument is used to investigate the impact of the amount of addition of an ideal bifocal simultaneous vision correction, both on image contrast and on visual performance. The instrument is validated through computer simulations of the<br />letter contrast and by equivalent optical experiments with an artificial eye (camera). Visual acuity (VA) was measured in four subjects (age: 34.3 6 3.4 years; spherical error: 2.1 6 2.7 diopters [D]) for low and high contrast letters and different amounts of addition.</p>
<h3><strong>Results</strong></h3>
<p>The largest degradation in contrast and visual acuity (~25%) occurred for additions around 62 D, while additions of 64 D produced lower degradation (14%). Low additions (1– 2 D) result in lower VA than high additions (3–4 D).</p>
<h3><strong>Conclusions</strong></h3>
<p>A simultaneous vision instrument is an excellent tool to simulate bifocal vision and to gain understanding of multifocal solutions for presbyopia. Simultaneous vision induces a pattern of visual performance degradation, which is well predicted by the degradation found in image quality. Neural effects, claimed to be crucial in the patients’ tolerance of simultaneous vision, can be therefore compared with pure optical effects. (Invest Ophthalmol Vis Sci. 2013;54:415–422) DOI:10.1167/iovs.12-11219</p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/experimental-simulation-of-simultaneous-vision-invest-ophthalmol-vis-sci/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
