<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ruiz, S. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/author/ruiz-s/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Wed, 23 Aug 2023 09:44:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Ruiz, S. | 2EyesVision</title>
	<link>https://www.2eyesvision.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multifocal contact lens vision simulated with a clinical binocular simulator (2022)</title>
		<link>https://www.2eyesvision.com/multifocal-contact-lens-visual-simulator/</link>
					<comments>https://www.2eyesvision.com/multifocal-contact-lens-visual-simulator/#respond</comments>
		
		<dc:creator><![CDATA[Barcala, X.]]></dc:creator>
		<pubDate>Tue, 06 Dec 2022 15:19:14 +0000</pubDate>
				<guid isPermaLink="false">https://talentiam-programs.com/?post_type=project&#038;p=22988506</guid>

					<description><![CDATA[The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and visual simulator.]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_divider et_pb_divider_0 et_pb_divider_position_ et_pb_space"><div class="et_pb_divider_internal"></div></div><div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Citation</h2>
<p>Barcala, X., Vinas, M., Ruiz, S., Hidalgo, F., Nankivil, D., Karkkainen, T., Gambra, E., Dorronsoro, D., &amp; Marcos, S.;<b> Multifocal contact lens vision simulated with a clinical binocular simulator.</b> Contact Lens and Anterior Eye 2022, 45(6):101716. For more information, <a class="link_loma" href="https://www.sciencedirect.com/science/article/pii/S1367048422001618" target="_blank" rel="noopener">click here.</a></p>
<h2></h2>
<h2 class="section-title u-h4 u-margin-l-top u-margin-xs-bottom">Abstract</h2>
<p>&nbsp;</p>
<div id="as005">
<h3 id="st010" class="u-h4 u-margin-m-top u-margin-xs-bottom">Purpose</h3>
<p id="sp0005">The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator.</p>
<p>&nbsp;</p>
</div>
<div id="as010">
<h3 id="st015" class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3>
<p id="sp0010">Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M−CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M−CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M−CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained.</p>
<p>&nbsp;</p>
</div>
<div id="as015">
<h3 id="st020" class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3>
<p id="sp0015">Both actual and simulated M−CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M−CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M−CLs ranged between −1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p &lt; 0.005).</p>
<p>&nbsp;</p>
</div>
<div id="as020">
<h3 id="st025" class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3>
<p id="sp0020">A simultaneous vision simulator accurately represented vision with M−CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M−CLs fitting.</p>
</div></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/multifocal-contact-lens-visual-simulator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
