<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Montagud Martinez, D. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/author/montagud-martinez-d/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Thu, 29 Oct 2026 09:56:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Montagud Martinez, D. | 2EyesVision</title>
	<link>https://www.2eyesvision.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in‑vitro and computational characterization to clinical validation</title>
		<link>https://www.2eyesvision.com/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-in-vitro-and-computational-characterization-to-clinical-validation/</link>
					<comments>https://www.2eyesvision.com/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-in-vitro-and-computational-characterization-to-clinical-validation/#respond</comments>
		
		<dc:creator><![CDATA[Esteban Ibañez, E.]]></dc:creator>
		<pubDate>Fri, 12 Jul 2024 08:37:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/?post_type=project&#038;p=22995015</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[
<div class="et_pb_section_0 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_0 et_pb_row et_block_row"><div class="et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_divider_0 et_pb_divider et_pb_space et_pb_divider_position_top et_pb_module preset--module--divi-divider--default"><div class="et_pb_divider_internal"></div></div><div class="et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default"><div class="et_pb_text_inner"><h2 id="Abstract" class="article-heading">Abstract</h2>
<p>Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs—several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCL</p>
</div></div></div></div></div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/simulation-of-daily-soft-multifocal-contact-lenses-using-simvis-gekko-from-in-vitro-and-computational-characterization-to-clinical-validation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
