<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Martínez-Plaza, E. | 2EyesVision</title>
	<atom:link href="https://www.2eyesvision.com/author/martinez-plaza-e/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.2eyesvision.com</link>
	<description>Seeing is believing</description>
	<lastBuildDate>Thu, 19 Jun 2025 13:33:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.2eyesvision.com/wp-content/uploads/2023/07/cropped-isologo-definitivo-2EyesVision-32x32.png</url>
	<title>Martínez-Plaza, E. | 2EyesVision</title>
	<link>https://www.2eyesvision.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator</title>
		<link>https://www.2eyesvision.com/improving-multifocal-contact-lens-fitting-by-replicating-their-fitting-guides-using-the-simvis-gekko-visual-simulator/</link>
					<comments>https://www.2eyesvision.com/improving-multifocal-contact-lens-fitting-by-replicating-their-fitting-guides-using-the-simvis-gekko-visual-simulator/#respond</comments>
		
		<dc:creator><![CDATA[Esteban Ibañez, E.]]></dc:creator>
		<pubDate>Thu, 19 Jun 2025 13:21:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.2eyesvision.com/?post_type=project&#038;p=22996190</guid>

					<description><![CDATA[Purpose: To evaluate the feasibility of implementing fitting guides for multifocal contact lenses (MCLs) using the SimVis Gekko visual simulator and, through a preliminary assessment with a novel metric (3D-VA, which integrates visual acuity at multiple distances and patient visual needs), determine whether this combined approach can optimise initial MCL selection. Methods: Twenty presbyopic subjects [&#8230;]]]></description>
										<content:encoded><![CDATA[<div><b>Purpose: </b>To evaluate the feasibility of implementing fitting guides for multifocal contact lenses (MCLs) using the SimVis Gekko visual simulator and, through a preliminary assessment with a novel metric (3D-VA, which integrates visual acuity at multiple distances and patient visual needs), determine whether this combined approach can optimise initial MCL selection.</div>
<div></div>
<div><b>Methods: </b>Twenty presbyopic subjects participated in this study using two methods to select on-eye MCLs from 4 manufacturers: (1) using the first step of the fitting guide, according to the patient&#8217;s addition need, to provide the MCLs recommended by the manufacturer and, (2) using SimVis Gekko simulations to obtain MCLs providing better 3D-VA, between the first and the first-alternative step of the fitting guides. Clinical measurements and metric calculations (3D-VA, perceptual score module, and direct preference) were conducted to compare the visual performance of the on-eye MCLsselected by both methods when differences existed.</div>
<div></div>
<div><b>Results: </b>SimVis Gekko selected the same combination of MCLs as the fitting guides in 59 % of the cases. In 28 %, SimVis Gekko chose the alternative step with differences greater than 0.05 in 3D-VA. In these latter cases, the 3D-VAsobtained with the on-eye MCLs indicated that SimVis Gekko selections were better in 62 % of cases, equal in 14 %, and worse in 24 %. The perceptual score module showed that SimVis Gekko selections were better in 62 % of cases, equal in 9 %, and worse in 29 %. The direct preference indicated that SimVis Gekko selections were better in 61 % of cases. Clinical measurements revealed that MCLsselected by SimVis Gekko had better Near Activity Visual Questionnaire scoresthan the fitting guide selection acrossall manufacturers (p = 0.02), indicating greater comfort and independence for near activities.</div>
<div></div>
<div><b>Conclusions: </b>SimVis Gekko can effectively replicate fitting guide steps and, in combinationwith the3D-VA metric, has the potential to become a tool that helps practitioners enhance MCL wearer satisfaction. This approach could improve the adoption and visual performance of MCLs among the presbyopic population,streamlining the fitting process.</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.2eyesvision.com/improving-multifocal-contact-lens-fitting-by-replicating-their-fitting-guides-using-the-simvis-gekko-visual-simulator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
